Compact local display with carrier frequency or inductive sensor for the evaluation of volume flows. All measurement results and parameters relevant for the process can be displayed directly on the VRG via the graphic display (illuminable) and changed by means of four membrane keys.


Local Displays (VTC/VIC)

with analog and frequency output, temperature measurement

Technical Data:

  • Carrier frequency or inductive pickup
  • Analog Output: 4 - 20 mA passive (2 wire)
  • Frequency output, freely scalable, Push Pull or NAMUR
  • 20 point linearization of the measured value, 3 banks
  • Control input
  • KEM interface (standard) or USB or HART
  • Ex Protection: ATEX Ex II 2G Ex ia IIC T4 Gb

Features:

  • High accuracy
  • Intuitive user interface
  • Remote control SW free of charge

Datasheet here


Local Displays (VTG/VIG)

for wall mount with analog and frequency output

Technical Data:

  • Carrier frequency or inductive pickup
  • Analog Output: 4 to 20 mA passive (2 wire)
  • Frequency output, freely scalable, Push Pull or NAMUR
  • 20 point linearization of the measured value, 3 banks
  • Control input
  • KEM interface (standard) or USB or HART
  • Ex Protection: ATEX Ex II 2G Ex ia IIC T4 Gb

Features:

  • High accuracy
  • Intuitive user interface
  • Remote control SW free of charge

Datasheet here


Local Display (FlowPod)

with HART and Exd certification

Technical Data:

  • Carrier frequency, inductive or Reed switch input
  • Analog Output: 4 to 20 mA passive (2-wire)
  • HART 7 interface
  • 2x configurable switch outputs for alarm, pulse or batch
  • Operating Temperature: ‐20 °C up to +75 °C [‐4 °F up to +167 °F]
  • 20+ point linearization of the measured value
  • Ingress Protection: IP66/68 - NEMA 4X
  • ATEX, IECEx

Features:

  • Explosion-proof (Exd/XP)
  • Lightweight DIN 1.4401 [AISI 316] stainless steel housing
  • Screwless design for quick and easy on-site installation
  • Calibration data transmission by memory card
  • FRAM memory

Datasheet here


Panel Mount Displays (FAS 100)

with analog and frequency output

Technical Data:

  • Frequency input for 24V digital signals
  • Analog Output: 4 to 20 mA
  • 24 V frequency output, freely scalable
  • 20 point linearization of the measured value
  • Control input and Control input
  • RS485 interface

Features:

  • High accuracy
  • Intuitive user interface
  • Remote control SW free of charge

Datasheet here


Wall Mount Displays (FAW 100)

with analog and frequency output

Technical Data:

  • Frequency input for 24V digital signals
  • Analog Output: 4 to 20 mA
  • 24 V frequency output, freely scalable
  • 20 point linearization of the measured value
  • Control input and Control input
  • RS485 interface
  • Power Supply: 24 V DC or 100 to 240 V AC

Features:

  • High accuracy
  • Intuitive user interface
  • Remote control SW free of charge

Datasheet here


Intrinsically Safe Supply Unit and separation amplifier (EWS)

to supply intrinsically safe pickups and amplifiers

Technical Data:

  • Open-Collector
  • PLC output active 24 V
  • NAMUR DIN 19234

Datasheet here