Contactless signal capturing from the operating medium is realized through the rotation of the KEM Flow Meter’s measuring insert, offering rapid system integration combined with an operating interface and parametrization options. Modular products enable our customers to provide the required data interfaces of frequency, analog, and digital outputs. They cover the scope of performance and expectations of users in various markets and applications. At the same time, we ensure that our products comply with legal explosion protection and EMC directives.


ECO Pulse Amplifiers

Single / double tap with different output functions

Power Supply (Vcc): 12 ... 28 VDC, regulated

Current Consumption: < 25 mA

Frequency Range: 1 ... 5.000 Hz; suitable for all KEM volumetric counters

Ambient Temperature: -40 °C ... +60 °C [-40 °F ... +140 °F]

Medium Temperature: -40 °C ... +80 °C [-40 °F ... +176 °F]

Output Signal: 1:1- Frequency or Direction signal & doubled Frequency scaled output values

Protection Class: 

  • Aluminium IP65
  • Stailness Steel IP68
  • with closed electical connection

Datasheet here


ECO1 Pulse Amplifiers

with single pickup, for screwing in for all KEM flow meters

Power Supply (Vcc): +12 up to 27 V DC, regulated

Current Consumption: < 20 mA

Frequency Range: 1 ... 5.000 Hz

Ambient Temperature: -40 °C ... +60 °C [-40 °F ... +140 °F]

Medium Temperature: -40 °C up to +150 °C [-40 °F up to +302 °F], depending on version

Output Signal: 1:1-frequency or direction signal & double frequency

Ingress Protection: IP 65

Datasheet here


Carrier-Frequency Pulse Amplifiers (VTE 04)

with single pickup, for direct mounting for all ZHM 01/1 and ZHM 01/2 in cartridge construction, as well as for the LFM

Power Supply (Vcc): UB: +5 up to 30 V DC

Current Consumption: IR < 1 mA

Frequency Range: 0.5 up to 5,000 Hz depending on flow meter

Ambient Temperature: -40 °C up to +80 °C [-40 °F up to +176 °F], depending on version

Medium Temperature: -40 °C ... +80 °C [-40 °F ... +176 °F]

Output Signal: Push-Pull, Open-Collector (option) or NAMUR

Ex Protection: 

  • ATEX: II 2G Ex ia IIC T4 Gb
  • IECEx:
    • Ex ia IIC T4 Gb cCSAus: Class I, Div. 1, Groups A, B, C, D ; T4
    • Ex ia IIC T4 Ga
    • Class I, Zone 0 AEx ia IIC T4 Ga

Datasheet here


Inductive Pickups and Amplifiers (IF und VIEG)

for extreme medium temperatures

Power Supply (Vcc): UB: +7 up to 29 V DC

Current Consumption: IR < 4 mA

Frequency Range: 7 up to 3,000 Hz depending on flow meter

Ambient Temperature: -40 °C up to +80 °C [-40 °F up to +176 °F]

Medium Temperature: max. +350 °C [+662 °F] depending on IF sensor

Output Signal: frequency output (various modes)

Ex Protection: II 2G EEx ia IIC T4-T6

Datasheet here


Fiber Optical Amplifier and Lightpulse Receiver (FOP und OPTV)

for applications in electrostatical painting systems

Power Supply (Vcc):

  • FOP 60/FOP 70: lithium battery

Ambient Temperature:

  • FOP 60
    • -20 °C up to +50 °C [-4 °F up to +122 °F]
  • FOP 70
    • -20 °C up to +70 °C [-4 °F up to +158 °F]
  • OPTV
    • -20 °C up to +60 °C [-4 °F up to +140 °F]

Ex Protection, intrinsically safe:

  • FOP 60
    • ATEX: II 2 G EEx ia IIC T4/T5/T6
    • CSA: Ex ia IIC; Class I, Zone 0, AEx ia IIC
  • FOP 70
    • ATEX: II 2G Ex ia IIC T4 Gb
    • IECEX: Ex ia IIC T4 Gb
  • OPTV
    • II2 G EEx ia IIC T6

Datasheet FOP 60 v FOP 70