36 Street no. 2, Quarter 2 Tel.: +84 (0)28 5402 9002 eMail: info@huynhbang.com |
---|
Contactless signal capturing from the operating medium is realized through the rotation of the KEM Flow Meter’s measuring insert, offering rapid system integration combined with an operating interface and parametrization options. Modular products enable our customers to provide the required data interfaces of frequency, analog, and digital outputs. They cover the scope of performance and expectations of users in various markets and applications. At the same time, we ensure that our products comply with legal explosion protection and EMC directives.
ECO Pulse Amplifiers
Single / double tap with different output functions
Power Supply (Vcc): 12 ... 28 VDC, regulated
Current Consumption: < 25 mA
Frequency Range: 1 ... 5.000 Hz; suitable for all KEM volumetric counters
Ambient Temperature: -40 °C ... +60 °C [-40 °F ... +140 °F]
Medium Temperature: -40 °C ... +80 °C [-40 °F ... +176 °F]
Output Signal: 1:1- Frequency or Direction signal & doubled Frequency scaled output values
Protection Class:
- Aluminium IP65
- Stailness Steel IP68
- with closed electical connection
Datasheet here
ECO1 Pulse Amplifiers
with single pickup, for screwing in for all KEM flow meters
Power Supply (Vcc): +12 up to 27 V DC, regulated
Current Consumption: < 20 mA
Frequency Range: 1 ... 5.000 Hz
Ambient Temperature: -40 °C ... +60 °C [-40 °F ... +140 °F]
Medium Temperature: -40 °C up to +150 °C [-40 °F up to +302 °F], depending on version
Output Signal: 1:1-frequency or direction signal & double frequency
Ingress Protection: IP 65
Datasheet here
Carrier-Frequency Pulse Amplifiers (VTE 04)
with single pickup, for direct mounting for all ZHM 01/1 and ZHM 01/2 in cartridge construction, as well as for the LFM
Power Supply (Vcc): UB: +5 up to 30 V DC
Current Consumption: IR < 1 mA
Frequency Range: 0.5 up to 5,000 Hz depending on flow meter
Ambient Temperature: -40 °C up to +80 °C [-40 °F up to +176 °F], depending on version
Medium Temperature: -40 °C ... +80 °C [-40 °F ... +176 °F]
Output Signal: Push-Pull, Open-Collector (option) or NAMUR
Ex Protection:
- ATEX: II 2G Ex ia IIC T4 Gb
- IECEx:
- Ex ia IIC T4 Gb cCSAus: Class I, Div. 1, Groups A, B, C, D ; T4
- Ex ia IIC T4 Ga
- Class I, Zone 0 AEx ia IIC T4 Ga
Datasheet here
Inductive Pickups and Amplifiers (IF und VIEG)
for extreme medium temperatures
Power Supply (Vcc): UB: +7 up to 29 V DC
Current Consumption: IR < 4 mA
Frequency Range: 7 up to 3,000 Hz depending on flow meter
Ambient Temperature: -40 °C up to +80 °C [-40 °F up to +176 °F]
Medium Temperature: max. +350 °C [+662 °F] depending on IF sensor
Output Signal: frequency output (various modes)
Ex Protection: II 2G EEx ia IIC T4-T6
Datasheet here
Fiber Optical Amplifier and Lightpulse Receiver (FOP und OPTV)
for applications in electrostatical painting systems
Power Supply (Vcc):
- FOP 60/FOP 70: lithium battery
Ambient Temperature:
- FOP 60
- -20 °C up to +50 °C [-4 °F up to +122 °F]
- FOP 70
- -20 °C up to +70 °C [-4 °F up to +158 °F]
- OPTV
- -20 °C up to +60 °C [-4 °F up to +140 °F]
Ex Protection, intrinsically safe:
- FOP 60
- ATEX: II 2 G EEx ia IIC T4/T5/T6
- CSA: Ex ia IIC; Class I, Zone 0, AEx ia IIC
- FOP 70
- ATEX: II 2G Ex ia IIC T4 Gb
- IECEX: Ex ia IIC T4 Gb
- OPTV
- II2 G EEx ia IIC T6