Supplier and Service Agent for
Industrial Equipment Made in Europe.

36 Street no. 2, Quarter 2
An Phu Ward, Thu Duc City
Ho Chi Minh City, Vietnam

Tel.: +84 (0)28 5402 9002
Fax: +84 (0)28 5402 9004

eMail: info@huynhbang.com

Digital Pressure Controllers for Gases with integrated Flow Measurement

The electronic red-y smart pressure controller combine the reliable technology of our digital mass flow controllers with electronic pressure control.

The devices automatically control a predefined process pressure and at the same time measure and/or limit the flow rate. On-the-fly switching between pressure control and flow control offers maximum flexibility.

PDF Datasheet

CORE FEATURES

√ 1 Device - 3 Funtions

√ Instrument Versions

√ It's red-y smart

√ Analog & Digital

√ Operating Status Indication

get red-y Software

√ Options

√ 3-Years Warranty


Technical Specifications red-y smart pressure controller

MEASURING & CONTROL RANGES PRESSURE

Pressure control

Absolute, differential or gauge pressure
Standard measuring ranges from 30 mbar up to 10 bar (graded)
Turndown ratio: 1 : 100

Back pressure control

Absolute, differential or gauge pressure
Standard measuring ranges from 30 mbar up to 10 bar (graded)
Dynamic range depending on the application

MEASURING RANGES FLOW

Air/Full scale freely selectable

Body size ¼” from 0 … 25 mln/min to 0 … 60 ln/min
Body size ½” from 0 … 60 ln/min to 0 … 450 ln/min

TURNDOWN RATIO & ACCURACY FLOW

“Standard”

Accuracy: ± 1.0% of full scale*
Turndown ratio: 1 : 50

“Hi-Performance”
(up to 150 ln/min)

Accuracy: ± 0.3% of full scale + ± 0.5% of reading*
Turndown ratio: 1 : 100

Pressure controller with external transmitter, special measuring ranges (e.g. 0-20 Pa) & customer-specific solutions on request

PERFORMANCE DATA

Media (real gas calibration)

Air*, O2*, N2, He, Ar, CO2, H2, CH4, C3H8 (other gases and gas mixtures on request)
*O2 & N2 are calibrated with air

Response time Flow Measurement

± 80ms
depending on device configuration & according to SEMI standard E17-1011, 5-100% of range under optimized conditions

Response time Pressure Measurement

150ms

Response time Pressure Control

Depending on the measuring section

Repeatability

± 0.2% of full scale (according to SEMI standard E56-0309)

Longterm stability

< 1% of measured value / year

Power supply

24 Vdc (18 – 30 Vdc), 15 Vdc on request

Current consumption Standard

Meter: max. 100 mA; Controller: max. 250 mA
(with valve type 8 max. 490mA)

Current consumption
Profinet RT / EtherCAT

Meter: max. 125 mA; Controller: max. 340 mA
(with valve type 8 max. 560mA)

Temperature (environment/gas)

0 – 50°C

Body Materials

Anodized aluminium,
optional stainless steel electropolished 1.4305 or 1.4404

Seals

FKM, EPDM, optional FFKM

Pressure

Vacuum up to 10 bar g

Pressure sensitivity

<0.2% / bar of reading (typical N2)

Temperature sensitivity

0.025% FS measuring range type / °C

Warm-up time

<1 sec. for full accuracy

INTEGRATION

Output signals digital

RS-485; Modbus RTU (Slave); Lab View-VIs available
Option: ProfiBus DP-V0, DP-V1 / Profinet RT / EtherCAT

Output signals analog

0..20 mA, 4..20 mA, 0..5 V, 1..5 V, 0..10 V, 2..10 V

Analog setpoints

Realizable with AD-converter (on request)

Process connection

G¼” (BSPP* female) up to 60 ln/min,
G½” (BSPP* female) up to 450 ln/min
*British Standard Pipe Parallel

Inlet section

None required

Electrical connection

Sub D plug, 9 pole

Mounting orientation

Any position (consult manufacturer above 5 bar or vertical mounting)

SAFETY

Test pressure

16 bara

Leak rate

< 1 x 10-6 mbar l/s He

Ingress protection class

IP50 or IP67

EMC

EN 61326-1

To top