ecom-J2KNpro

EXTREMELY broad reach

Performing flue gas analyser with remote control module via radio

  • Radio remote controller with high functionality
  • Up to 70 meters stable coverage
  • Gas cooler for perfect NOx/SO2 measurement (depending on selected model variant)
  • Robust aluminium housing fitted in alu-framed transport caseUp to 6 sensor options (Longlife sensors)
  • Brushless high-performance pump (2.6 liters/minute)
  • CO sensor exceeding protection without measurement interruption
  • Multi-step sample gas filtering
  • Electronic condensate monitoring
  • Integral soot measurementInstrument inner heating
  • Backlit display and keypad

 

 

 Technical equipment

  • With O2/CO (H2 comp.) Longlife sensors (life span higher than 4 years by normal load)
  • Automatic CO-switch-off and sensor purging (without measurement interruption)
  • Condensate trap resp. gas cooler incl. electronic condensate monitoring (depending on selected model variant)
  • Powerfull Lithium-Ion battery
  • Gas cooler with automatic condensate evacuation
  • Integral thermal quick-printer
  • High-value gas sampling probe incl. thermocouple, fixation cone and high-value 3-chamber gas sampling tubing
  • Status display for indication of basic functions, adjustments and warning messages
  • Complete in ultra-light, robust aluminium housing
  • T-Room sensor / T-Room stick (according to request resp. model variant)
  • Integral soot measurement (application-related covered in standard delivery scope)
  • Fitted in spacious aluminium-framed transport case with comfort shoulder carrying strap
  • Calibration certificate - issued after 100% sensors calibration into climatic chamber
  • Free downloadable PC software

Radio remote controller

  • High coverage for bridging distances between measurement place (gas opening) and adjustment system (e.g. burner, control panel, etc.)
  • Incl. thermocouple input, mini USB connector (data transfer to laptop/PC), SD card slot
  • Backlit foil keypad and high-value colour TFT display
  • Indication, printout and recording of measurement data
  • Complete instrument operation command (i. a. manual CO switch-off, start and end of measurements, data processing, …)
  • Stable data transfer via radio (highest avoidance of interferences, bypass of metal or concrete obstacles, automatic connection, no abrupt disconnection, keeping of al measurement values as well as automatic build-up and restoration of radio connection)

Dimension

  • (L x H x W): approx. 450 x 315 x 250 mm resp. 510 x 330 x 250 mm (depending on selected model version)

Weight

  • Approx. 12 kg (complete in transport case)

Options

  • NOx calculation via NO sensor or NOx measurement (NO + NO2 sensors) possible
  • Further optional sensors (SO2, H2S, H2, CO%)
  • Higher resolution and accuracy in NOLow (0-500 ppm) resp. NO2 Low (0-100 ppm) range
  • CxHy measurement via catalytic measurement principle (Pellistor)
  • Measurement of flow velocity in exhaust gas
  • Wi-Fi or Bluetooth Low Energy option

Options package biogas for raw gas analysis

  • CH4 (NDIR) Sensor, 0-100 %
  • H2S (EC) Sensor, 0-5000 ppm
  • Viton-Entnahmeschlauch, 3 m

Accessories

  • Various gas filtering options – i. a. for recurring solid combustibles measurement
  • Various temperature sensors (contact sensor, surface sensor, …) for differential temperature measurement (e.g. water run-in and water run-out temperatures)
  • Alternative probe tip lengths and probe tip type (high-temperature) resp. heat protection shield

Please dowload datasheet here