Weishaupt burners - Successful to replace 3 old light oil burners from other by Weishaupt gas burners | Tripod Bien Hoa | 2026

3 x WM-G20/2-A ZM - Gas CNG @ Steam Boiler 2 t/h @ Tripod
Weishaupt burners - Successful to replace 3 old light oil burners from other by Weishaupt gas burners | Tripod Bien Hoa | 2026

Data of old burners system before replacement by new Weishaupt gas burners

ApplicationSteam boiler
Application capacity2 t/h
Existing burners3 sets of old light oil burners from other brand
Existing burners typeMK 3 _ Light oil
Burner capacityNo nameplate showing up in kW
Burner controllerMechanical control box LAL 2.25

Operating mode &

operating issues

  • ON / OFF (two-stage via two pressure switches)
  • Intermittent operation
  • Spare parts replacement more frequently.
  • Consumption too much oil fuel
  • Cannot improve combustion / system efficiency.
  • Boilers cleaning issues because of oil fuel.
  • Too much noise in operation.
  • Cannot connect / integrate to BMS / PLC system
Commissioning in1997


New Weishaupt gas burners

Product information - Weishaupt monoblock burner WM20

ApplicationSteam boiler
Location on systemMain burner
Application capacity2 t/h
Weishaupt burner typeWM-G20/2-A ZM
Fuel gas typeCNG gas
Burner capacity150 - 2100 kW
Burner quantity03 complete set
Digital combustion managerW-FM 200
Equipped for more flexibilityVSD O2 trim Gas flow meter Digital Interfaces (BMS / PLC)
Operating mode
  • Modulating control with pressure controller KS40-108 (special design / optimizing for Weishaupt burners)
  • Continuous operation > 24h
  • VSD (variable speed drive)
  • Oxygen trim system

Special features /

Customer benifits

  • Modern Weishaupt gas burner using digital combustion manager W-FM 200 with clear text control and display unit ABE, easier for operation and troubleshooting later with errors code and errors details displayed.
  • Burners capacity controlled by pressure controller KS40-108 which are in deep fine-tuning for optimizing operation.
  • Minimization of spare parts replacement.
  • Burners with VSD (variable speed drive) reduced both its electrical consumption and noise emissions at partial load. 
  • Increase a system’s safety and efficiency, save more fuel cost by using O2 trim system combination with W-FM 200
  • Ready to connect to BMS (Building Management System) or PLC system via digital interface integrated.
  • Gas fuel consumption management via gas flow meter with impulse output / easy to integrate to W-FM 200 or into other control system.
  • Gas valve proving integrated to double solenoid valve DMV with testing procedure via gas pressure switch GW and W-FM 200.
  • Outstanding price-to-performance ratio
  • Versatility
  • User-friendly concept
  • Particularly quiet operation
Scope of deliveryBurner complete set + Full gas train accessories + Control panel + Commissioning
Commissioning in2026
Technical information of burner
Other technical document


Project images:

✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨

✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨✨

HBC TSM B.B

Year: 2026

Ask a question
Do you have questions or need?
Personal information:
Company information:
I would like to learn more about:
Interested in another product or solution:
Note
Attachment file (Supported file formats:.jpg,.png,.pdf,.docx,.xlsx,.zip)
Related applications
Vaisala (K-Patents) - Safe-Drive Process Refractometer PR-23-SD _ AU17106-M4_Bai Bang Paper
Vaisala (K-Patents) - Safe-Drive Process Refractometer PR-23-SD _ AU17106-M4_Bai Bang Paper
PR-23-SD-62-FXS-GP-AA _ s/n R015727 _ ACK 171027 (successor by Vaisala Polaris™ PR53SD)
Optris_Success story_Replacement Optris IR camera PI 400 by PI 450i_Glass industry_Ho Chi Minh City_CC005100_Long Nhien Auto Glass
Optris_Success story_Replacement Optris IR camera PI 400 by PI 450i_Glass industry_Ho Chi Minh City_CC005100_Long Nhien Auto Glass
Replacement Optris IR camera PI 400 by PI 450i