Hygro transducer and hygrothermal transducer

Hygrometric

The humidity measuring probes are suitable for both air-conditioning applications and humidity measurements in industrial applications. The high resistance of the sensing element to water is an advantageous feature which allows permanent use of the device in high humidity applications through to saturation.

 

wrench flow connection plug
Maintenance-free
Resistance, current,
and voltage outputs
No voltage
supply

 

GENERAL TECHNICAL DATA

 
Measurement medium Air, pressureless (non-aggressive)
Outputs 4 to 20 mA, 0 to 20 mA, 0 to 10 V, as well as various resistance outputs
Voltage supply DC 24 V (standard), not required for passive version
Version Indoor and duct version
Approvals GOST
Protection type IP20 indoor version, IP64 duct version
Application Air-conditioning and ventilation technology, greenhouses, ripening chambers, fruit and vegetables (storage)
Measuring range RH = 0/30 to 100 % RH, T = -40 to +80 °C
Sensing element Hygrometric (water-resistant element)
Accessories Holders, sun and rain protection, filter tubes
Special features Resistance, current, or voltage outputs can be used permanently in high humidity applications up to 100 % RH (duct version), no voltage supply required for passive devices, sensing element largely maintenance-free in normal recirculated air
Related products
Hygro transducer and hygrothermal transducer (capacitive)
Hygro transducer and hygrothermal transducer (capacitive)

For applications in the air-conditioning sector

This measuring probe is for versatile ventilation and air conditioning applications. It is particularly easy to install, has a robust form, and uses reliable humidity measurement technology.

 

display wrench flow connection
2-line LCD-display
as optional extra
Rod, indoor,
wall-mounted,
and duct version
Current and
voltage outputs

 

Hygro transducer, hygrothermal transducer, and CO2 measuring probe
Hygro transducer, hygrothermal transducer, and CO2 measuring probe

For facility management and climate monitoring

This measuring probe is mainly used in heating engineering, air-conditioning, and ventilation technology. It sets itself apart in particular through high measuring accuracy, long-term stability, and chemical resistance.

 

display wrench flow connection
LCD display
Indoor, wall-mounted,
duct, and
rod versions
Current, voltage,
or Modbus output

 

JUMO Wtrans E01
JUMO Wtrans E01

Measuring probe for humidity, temperature, and CO2

The Wtrans E01 measuring probe is used in combination with a Wtrans receiver for recording measured values using digital sensors for humidity, temperature, and CO2. Other measurands can be derived from the determined measured values.

 

display flow connection wrench
LCD display with
background lighting
2 inputs for
measured value
recording
No wiring work