Push-in RTD temperature probe 902120
With terminal head form B
Push-in RTD temperature probes are predominantly used for temperature measurement in liquid and gases. Application areas include air conditioning and refrigeration technology, process technology as well as heating, furnace, and apparatus engineering.
|
Single/double
RTD temperature probe |
Interchangeable
measuring insert |
Transmitter
available |
GENERAL TECHNICAL DATA |
| Option | Head transmitter, three-wire or four-wire circuit, sensor Pt500 or Pt1000 |
| Protection type | IP65 |
| Terminal head | Form B, BUZ, BUZH, BBK |
| Protection fitting | Stainless steel 1.4571 |
| Sensor | Pt100 |
| Operating temperature | -50 to +600 °C |
| Areas of application | Plant engineering, industrial heating plants, drying plants, construction material machines |
| Process connection | Flange, compression fitting |
| Measuring circuits | 1/2 |
| Approvals | Metrological registration, SIL |
| Special features | Interchangeable measuring insert |
Universal receiver for JUMO wireless measuring probes
The Wtrans receiver T01, in combination with suitable Wtrans transmitters, is used for the mobile or stationary measurement of the following physical measurands: temperature, pressure, and humidity. The wireless sensor technology also works in a harsh industrial environment.
|
Up to 4 analog
outputs |
No wiring work
required |
Customer-specific
linearization |
For thermocouples and RTD temperature probes
DIN EN 50446 defines the terminal head design types A and B, which differ in size and also slightly in their shape. Aluminum or plastic is used, depending on the application. These design types are suitable for the installation of a two-wire transmitter.
|
Various
materials |
Sealable versions
|
Installation of
a transmitter |
For thermocouples and RTD temperature probes
Screw-in thermowells are used for installing thermocouples and RTD temperature probes when replacement without draining the system and/or pressure resistance is required. Pressure stability is temperature dependent and specified in the data sheet.
|
Operating pressure
up to 450 bar |
Thermometers can
be replaced without emptying the system |
Low investment
costs |